HiBuild 200 Acrylic Low Sheen

Price range: $127.20 through $275.60

High Build Water Proofing Membrane ? HiBuild 200 is specifically designed for coating cement based building elements.

  • Next day delivery
  • Top quality products
  • Money back guarantee

Description

High Build Water Proofing Membrane ? HiBuild 200 is specifically designed for coating cement based building elements.

When dry, it remains highly flexible and elastomeric for the lifetime of the paint system.

These attributes aid weather tightness by bridging small fissures and cracks that can develop in cementitious substrates.

download product specification Download material safety data
Weight10 kg
DimensionsN/A
Product Features

Remains flexible and elastic ? aids weather tightness water proofing by bridging small fissures and cracks Excellent hold-out characteristics ? gives uniform gloss levels on textured and coarse surfaces Superb flow control ? can be applied evenly; even on heavily textured surfaces Mould and fungus growth inhibitors ? ensures paint condition and appearance is maintained

Typical Area of Use

Upgrading of previously coated cementitious substrates in sound condition Coating of new cementitious substrates Fine stipple texturing

Typical Substrates

Concrete walls Cementitious cladding Brick and block work Solid Plaster finishes Stucco Tilt Slab

Color and Gloss

Gloss level and description ? low sheen 5% @ 60 degrees Available in white, pastel, mid tone, dark and extra bright colours

Surface preparation

General preparation of the surface to be painted should be completed before commencing application. All loose material must be removed and surface damage or imperfections made good. The surface must be clean, dry and free of contaminants. Weathered surfaces should be water-blasted and any contaminated surfaces etched and cleaned. Cracks should be filled with elastomeric filler after the application of PaintPlus Masonry Sealer. Moss and mould infected areas should be treated and water blasted. Prepare glossy areas by acid etching or grinding and thoroughly cleanse with a water blaster or a soft brush and hose to remove release agent residues and loose particles.

Application schedule

Touch dry 30 minutes Re-coat time (minimum) 4 hours Practical coverage 5?10 square meters per litre Dry film thickness @ 5 square meters per litre 91 microns per coat Usual no of coats ? 2 Application is not recommended if the surface and/ or air temperature is less than 10?C or is liable to fall below 10?C during the drying period.

Application methods

Application by airless spray gun is recommended to attain specified wet film builds. Airless spray minimum 150 bars (2,500lb/sq in) Tip size 19?21 thou A 16?20mm nap roller or lambskin roller may also be used to apply HiBuild 200

Clean up and thinning

Clean up all equipment with water. HiBuild 200 should not be thinned except to aid penetration on porous substrates ? a maximum of 50mls of water per litre may be added on the first coat for this purpose. Excessive thinning will have a detrimental impact on the features of this product.

Safety

Read label before use and keep out of reach of children. If medical advice is needed: have product container or label at hand. Wear protective clothing such as overalls, goggles and gloves and ventilate working areas. Wash any paint deposits off skin. If sanding wear face mask to avoid inhaling dust particles.

Precautions

Specified film builds of 200 microns wet film build (5 square meters per litre) must be attained to gain the benefits of the elastomeric water proofing benefits of this coating

Environmental Qualities

Manufactured in a carbon neutral certified facility ? ISO 14064-1 VOC 0gms per litre EC07-13 Ecolabel certified ? Environmental Choice EC07-13 Licence number 0703012

Primer/Sealer Requirements

Unpainted surfaces Apply 1 coat of PaintPlus Masonry Sealer Previously painted surfaces Prime repairs and bare areas with PaintPlus Masonry Sealer

Select Size (L):

4 Litres, 10 Litres

Select Base:

White Base, Tint Base, Ultra Deep Base

Quantity Calculator

var gform;gform||(document.addEventListener("gform_main_scripts_loaded",function(){gform.scriptsLoaded=!0}),document.addEventListener("gform/theme/scripts_loaded",function(){gform.themeScriptsLoaded=!0}),window.addEventListener("DOMContentLoaded",function(){gform.domLoaded=!0}),gform={domLoaded:!1,scriptsLoaded:!1,themeScriptsLoaded:!1,isFormEditor:()=>"function"==typeof InitializeEditor,callIfLoaded:function(o){return!(!gform.domLoaded||!gform.scriptsLoaded||!gform.themeScriptsLoaded&&!gform.isFormEditor()||(gform.isFormEditor()&&console.warn("The use of gform.initializeOnLoaded() is deprecated in the form editor context and will be removed in Gravity Forms 3.1."),o(),0))},initializeOnLoaded:function(o){gform.callIfLoaded(o)||(document.addEventListener("gform_main_scripts_loaded",()=>{gform.scriptsLoaded=!0,gform.callIfLoaded(o)}),document.addEventListener("gform/theme/scripts_loaded",()=>{gform.themeScriptsLoaded=!0,gform.callIfLoaded(o)}),window.addEventListener("DOMContentLoaded",()=>{gform.domLoaded=!0,gform.callIfLoaded(o)}))},hooks:{action:{},filter:{}},addAction:function(o,r,e,t){gform.addHook("action",o,r,e,t)},addFilter:function(o,r,e,t){gform.addHook("filter",o,r,e,t)},doAction:function(o){gform.doHook("action",o,arguments)},applyFilters:function(o){return gform.doHook("filter",o,arguments)},removeAction:function(o,r){gform.removeHook("action",o,r)},removeFilter:function(o,r,e){gform.removeHook("filter",o,r,e)},addHook:function(o,r,e,t,n){null==gform.hooks[o][r]&&(gform.hooks[o][r]=[]);var d=gform.hooks[o][r];null==n&&(n=r+"_"+d.length),gform.hooks[o][r].push({tag:n,callable:e,priority:t=null==t?10:t})},doHook:function(r,o,e){var t;if(e=Array.prototype.slice.call(e,1),null!=gform.hooks[r][o]&&((o=gform.hooks[r][o]).sort(function(o,r){return o.priority-r.priority}),o.forEach(function(o){"function"!=typeof(t=o.callable)&&(t=window[t]),"action"==r?t.apply(null,e):e[0]=t.apply(null,e)})),"filter"==r)return e[0]},removeHook:function(o,r,t,n){var e;null!=gform.hooks[o][r]&&(e=(e=gform.hooks[o][r]).filter(function(o,r,e){return!!(null!=n&&n!=o.tag||null!=t&&t!=o.priority)}),gform.hooks[o][r]=e)}});